  • Magnetic Starter
  • Type Full Voltage, Magnetic, Non-Combination, Non-Reversing
  • Current Rating 18 Ampere
  • Phase 3
  • Coil Voltage 110 VAC at 50 Hz, 115 to 120 VAC at 60 Hz
  • Size NEMA 0
  • Enclosure Type Open
  • Overloads 3-Phase 3-Leg Block Thermal Overload Relay
  • Construction Standard NEMA
  • Includes Holding Interlock, Pressure Terminal for Line and Load Connection

Features / Benefits

  • Magnetic Motor Starters May be Used for Starting Full Voltage, Non-Reversing, Single Speed AC Motors Upto 1600 Horsepower, 600 Volts Maximum, Providing Protection to the Motor Against Running or Stalled Overloads
  • Their Compact Size and Ease of Wiring Make them Especially Suitable for Motor Control Centers, Custom Type Control Panels and Switchgear Equipment
  • Toolless Contactor Disassembly (Sizes 00-4) Allows Quick Access for Inspection and Maintenance
  • Just Release Two Retainers and Pull a Clip to Get at Magnet, Coil and Contacts
  • Saddle Clamp Terminals (Sizes 00-1) Accommodate Ring, Spade and Stripped Wire Leads and Carry Permanent Stamped-In Identification
  • Staggered Arrangement Makes Wiring Easier and Helps Prevent Shorting Between Phases
  • Current Carrying Components Contact Tips Are Weld Resistant Silver Cadmium Oxide (Fine Silver on Sizes 00 and 0 Only)
  • Contacts Are Installed in a Wedge Configuration for Positive Make with Minimum Bounce
  • Class 20 Overload Protection
  • Visual Trip Indicator with Manual Reset to Avoid Surprise Restarts
  • Reset Occurs on Arm Upstroke So a Tripped Condition Cant be Overridden by Holding the Arm Down
  • Manual Weld Check Provides a Convenient Test Against Welding of Overload Relay Contacts
  • Just Depress the Weld Check Operator to Trip the Relay, Run a Simple Continuity Test Across the Relay Contacts, then Depress the Manual Reset to Return the Starter to Service
  • Optional Isolated No Contact on the Overload Relay Provides Means of Direct Interface with Programmable Controller or Computer to Monitor Performance and Diagnose Faults
  • Dual Bimetals Anticipate Overloads, Responding to Rising Current and Temperature with Faster Tripping on Severe Overloads for Better Motor Protection
  • Trip Points Are Factory Calibrated for Accuracy
  • +/-10 Percent Trip Adjustment by Turning a Dial in the Overload Relay Face Allows Tuning the Protection to the Motor on the Spot

CR306B002 STARTER

$354.15 / EA
Availability: 5 EA
SKU
CR306B002
Manufacturer:
  General Electric
By placing an order you agree to Terms & Conditions
EA
More Information
Commodity Level DescripNEMA Non-Combination Starters
Brand NameSeries CR306
ManufacturerGeneral Electric
UPC783166353615
UNSPSC39121521
Commodity Code41350
SizeNEMA 0
Phase3
Overloads3-Phase 3-Leg Block Thermal Overload Relay
TypeFull Voltage, Magnetic, Non-Combination, Non-Reversing
Current Rating18 Ampere
Construction StandardNEMA
Coil Voltage110 VAC at 50 Hz, 115 to 120 VAC at 60 Hz
Enclosure TypeOpen
Additional InfoIncludes Holding Interlock, Pressure Terminal for Line and Load Connection